骨锚式助听器——临床应用与研究进展

石静华, 夏寅. 骨锚式助听器——临床应用与研究进展[J]. 临床耳鼻咽喉头颈外科杂志, 2017, 31(8): 597-600. doi: 10.13201/j.issn.1001-1781.2017.08.006
引用本文: 石静华, 夏寅. 骨锚式助听器——临床应用与研究进展[J]. 临床耳鼻咽喉头颈外科杂志, 2017, 31(8): 597-600. doi: 10.13201/j.issn.1001-1781.2017.08.006
SHI Jinghua, XIA Yin. Clinical application and recent advance in BAHA[J]. J Clin Otorhinolaryngol Head Neck Surg, 2017, 31(8): 597-600. doi: 10.13201/j.issn.1001-1781.2017.08.006
Citation: SHI Jinghua, XIA Yin. Clinical application and recent advance in BAHA[J]. J Clin Otorhinolaryngol Head Neck Surg, 2017, 31(8): 597-600. doi: 10.13201/j.issn.1001-1781.2017.08.006

骨锚式助听器——临床应用与研究进展

详细信息
    通讯作者: 夏寅,E-mail:xiayin3@163.com
  • 中图分类号: R764.5

Clinical application and recent advance in BAHA

More Information
  • 加载中
  • [1]

    韩东一. 中国聋病防治现状[J]. 中华耳科学杂志,2007, 5(4):345-349.

    [2]

    TJELLSTRÖM A, LINDSTRÖM J, HALLÉN O, et al. Osseointegrated titanium implants in the temporal bone. A clinical study on bone-anchored hearing aids[J]. Am J Otol,1981,2:304-310.

    [3]

    TJELLSTROM A,GRANSTROM G. Long-term follow-up with the bone-anchored hearingaid:a review of the first 100 patients between 1977 and 1985[J].Ear Nose Throat J,1994,73:112-114.

    [4]

    CASS S P, MUDD P A.Bone-anchored hearing devices: indications, outcomes,and the linear surgical technique[J]. Oper Tech Otolaryngol,2010,21:197-206.

    [5]

    邱建华,韩宇.BAHA的临床应用与手术适应症[J].中国医学文摘耳鼻咽喉科学,2012,27(2):64-65.

    [6]

    夏寅,张华.骨锚式助听器植入的手术临床分析[J].中华耳鼻咽喉头颈外科杂志,2013,48(8):640-643.

    [7]

    MYLANUS E A, VAN DER POUW K C, SNIK A F,et al.Intraindividual comparison of the bone-anchored hearing aid and air-conduction hearing aids[J].Arch Otolaryngol Head Neck Surg,1998,124:271-276.

    [8]

    DE WOLF M J, HENDRIX S, CREMERS C W, et al. Better performance with one-anchored hearing aid than acoustic devices in patients withsevere air-bone gap[J]. Laryngoscope, 2011,121:613-616.

    [9]

    VANEECLOO F M, RUZZA I, HANSON J N,et al. The monaural pseudo-stereophonic hearing aid (BAHA) in unilateral total deafness: a study of 29patients[J]. Rev Laryngol Otol Rhinol (Bord),2001,122:343-350.

    [10]

    LIN L M, BOWDITCH S, ANDERSON M J, et al. Amplification in the rehabilitation of unilateral deafness: speech in noise and directional hearing effects with bone-anchored hearing and contralateral routing of signal amplification[J]. Otol Neurotol,2006,27: 172-182.

    [11]

    SNIK A F, BOSMAN A J, MYLANUS E A, et al. Candidacy for the bone-anchored hearing aid[J]. Audiol Neurootol,2004,9:190-196.

    [12]

    DE WOLF M J, HOL M K, HUYGEN P L, et al. Nijmegen results with application of a bone-anchored hearing aid in children: simplified surgical technique[J]. Ann Otol Rhinol Laryngol,2008,117:805-814.

    [13]

    夏寅, 张华, 张文阳.软带baha应用及相关听力学评估[J].听力学及言语疾病杂志,2014,22(1):5-8.

    [14]

    HODGETTS W E, SCOLLIE S D, SWAIN R.Effects of applied contact force and volume control setting on output force levels of the BAHA Softband[J]. Int J Audiol,2006,45:301-308.

    [15]

    HEYWOOD R L, PATEL P M, JONATHAN D A.Comparison of hearing thresholds obtained with Baha preoperative assessment tools and those obtained with the osseointegrated implant[J].Ear Nose Throat J,2011,90:E21-27.

    [16]

    BERGLUNDH T,ABRAHAMSSON I,LANG N P, et al.De novo alveolar bone formation adjacent to endosseous implants[J].Clin Oral Implants Res, 2003,14:251-262.

    [17]

    FABER H, DUN C, NELISSEN R, et al. Bone-anchored hearing implant loading at 3 weeks: stability and tolerability after 6 months[J]. Otol Neurotol,2013,34: 104-110.

    [18]

    MCLARNON C, JOHNSON I, DAVISON T, et al. Evidence for early loading of osseointegrated implants for bone conduction at 4 weeks[J]. Otol Neurotol,2012,33: 1578-1582.

    [19]

    WAZEN J J, DAUGHERTY J, DARLEY S,et al.Three week loading for the Baha BI-300? implant system[J].Am J Otolaryngol,2015,36:195-199.

    [20]

    杨仕明,邹艺辉.骨锚式助听器(BAHA)临床应用展望[J].听力学及言语疾病杂志,2011,19(5):391-393.

    [21]

    HOUGH J, HIMELICK T, JOHNSON B. Implantable bone conduction hearing device: Audiant bone conductor. Update on our experiences[J]. Ann Otol Rhinol Laryngol, 1986,95:498-504.

    [22]

    SIEGERT R. Partially implantable bone conduction hearing aids without a percutaneous abutment (Otomag): technique and preliminary clinical results[J]. Adv Otorhinolaryngol,2011,71:41-46.

    [23]

    DEVōZE A, ROSSETTO S, MELLER R, et al. Switching from a percutaneous to a transcutaneous bone anchored hearing system: the utility of the fascia temporalis superficialispedicled flap in case of skin intolerance[J]. Eur Arch Otorhinolaryngol,2015,272:2563-2569.

    [24]

    DIMITRIADIS P A, FARR M R, ALLAM A,et al.Three year experience with the cochlear BAHA attract implant: a systematic review of the literature[J].BMC Ear Nose Throat Disord,2016,16:12-12.

    [25]

    BRIGGS R, VAN HASSELT A, LUNTZ M,et al.Clinical performance of a new magnetic bone conduction hearing implant system: results from aprospective, multicenter, clinical investigation[J].Otol Neurotol,2015,36:834-841.

    [26]

    SHARMA S, REDDY-KOLANU G, MARSHALL A H. UK tertiary centre experience of outcomes from osseointegrated transcutaneous magnetic boneconduction hearing system implanted in twenty-five patients using a linear incision technique[J].Clin Otolaryngol,2016,[Epub ahead of print]

  • 加载中
计量
  • 文章访问数:  436
  • PDF下载数:  437
  • 施引文献:  0
出版历程
收稿日期:  2017-01-16

目录