振动声桥植入适应证

吴皓, 黄琦. 振动声桥植入适应证[J]. 临床耳鼻咽喉头颈外科杂志, 2013, 27(16): 871-873. doi: 10.13201/j.issn.1001-1781.2013.16.008
引用本文: 吴皓, 黄琦. 振动声桥植入适应证[J]. 临床耳鼻咽喉头颈外科杂志, 2013, 27(16): 871-873. doi: 10.13201/j.issn.1001-1781.2013.16.008
WU Hao, HUANG Qi. Indications of vibrant soundbridge implantation[J]. J Clin Otorhinolaryngol Head Neck Surg, 2013, 27(16): 871-873. doi: 10.13201/j.issn.1001-1781.2013.16.008
Citation: WU Hao, HUANG Qi. Indications of vibrant soundbridge implantation[J]. J Clin Otorhinolaryngol Head Neck Surg, 2013, 27(16): 871-873. doi: 10.13201/j.issn.1001-1781.2013.16.008

振动声桥植入适应证

详细信息
    通讯作者: 吴皓, E-mail:ent@xinhua-ent.com
  • 中图分类号: R764.5

Indications of vibrant soundbridge implantation

More Information
  • 加载中
  • [1]

    TRUY E, PHILIBERT B, VESSON J F, et al.Vi-brant soundbridge versus conventional hearing aid insensorineural high-frequency hearing loss:aprospec-tive study[J].Otol Neurotol, 2008, 29:684-687.

    [2]

    RAMEH C, MELLER, R, LAVIEILLE J P, et al. Long-term patient satisfaction with different middle ear hearing implants in sensorineural hearing loss[J]. Otol Neurotol, 2010, 31:883-892.

    [3]

    RICCI G, VOLPE A D, FARALLI M, et al.Bone an-chored hearing aid in congenital aural atresia:person-al experience[J].Int J pediatr Otorhinolaryngol, 2011, 75:342-346.

    [4]

    DEELAU F, CREMERS C, HEYNING P.Diagnosis and management strategies in congenital aural atresia of external auditory canal[J].Br J Audiol, 1999, 33:313-327.

    [5]

    BAUMGARTNER W D, BOHEIM K, HAGEN R, et al.The vibrant soundbridge for conductive andmixed hearing losses:European multicenter study re-sults[J].Adv Otorhinolaryngol, 2010, 69:38-50.

    [6]

    DUMON T.Vibrant soundbridge middle ear implantin otosclerosis:technique-indication[J].Adv Otorhi-nolaryngol, 2007, 65:320-321.

    [7]

    VENAIL F, LAVIEILLE J P, MELLER R, et al.New perspectives for middle ear implants:first re-sults in otosclerosis with mixed hearing loss[J].La-ryngoscope, 2007, 117:552-555.

    [8]

    JAN K, WOLFGANG A, RAINRE S.Round window stimulation with an implantable hearing aid combined with autogenous reconstruction of the auricle-a new approach[J].ORL J Otorhinolaryngol Relat Spec, 2006, 68:378-385.

    [9]

    COLLETTI V, SOLI S D, CARNER M, et al. Treatment of mixed hearing loss via implantation of a vibratory transducer on the round window[J]. Int J Audiol, 2006, 45:600-608.

    [10]

    VERHAEGEN V J, MULDER J J, CREMERS C W, et al. Application of active middle ear implants in patients with severe mixed hearing loss[J]. Otol Neurotol, 2012, 33:297-301.

    [11]

    LINDER T, SCHLEGEL C, DEMIN N, et al.Ac-tive middle ear implants in patients undergoing subto-tal petrosectomy:new application for the VibrantSoundbridge device and its implication for lateral cra-nium base surgery[J].Otol Neurotol, 2009, 30:41-47.

    [12]

    LUETJE C M, BRACKMAN D, BALKANY T J, etal.PhaseⅢclinical trial results with the VibrantSoundbridge implantable middle ear hearing device:aprospective controlled multicenter study[J].Otolar-yngol Head Neck Surg, 2002, 126:97-107.

    [13]

    STERKERS O, BOUCARRA D, LABASSI S, et al.A middle ear implant, the Symphonix Vibrant Sound-bridge:retrospective study of the first 125patientsimplanted in France[J].Otol Neurotol, 2003, 24:427-436.

  • 加载中
计量
  • 文章访问数:  61
  • PDF下载数:  48
  • 施引文献:  0
出版历程
收稿日期:  2013-01-07

目录