听神经病人工耳蜗植入术中EABR监测及其疗效评估

王斌, 曹克利, 魏朝刚. 听神经病人工耳蜗植入术中EABR监测及其疗效评估[J]. 临床耳鼻咽喉头颈外科杂志, 2013, 27(10): 449-454. doi: 10.13201/j.issn.1001-1781.2013.10.005
引用本文: 王斌, 曹克利, 魏朝刚. 听神经病人工耳蜗植入术中EABR监测及其疗效评估[J]. 临床耳鼻咽喉头颈外科杂志, 2013, 27(10): 449-454. doi: 10.13201/j.issn.1001-1781.2013.10.005
WANG Bin, CAO Keli, WEI Chaogang. Cochlear implantation in patients with auditory neuropathy assisted by intra-operative EABR and the therapeutic effect evaluation[J]. J Clin Otorhinolaryngol Head Neck Surg, 2013, 27(10): 449-454. doi: 10.13201/j.issn.1001-1781.2013.10.005
Citation: WANG Bin, CAO Keli, WEI Chaogang. Cochlear implantation in patients with auditory neuropathy assisted by intra-operative EABR and the therapeutic effect evaluation[J]. J Clin Otorhinolaryngol Head Neck Surg, 2013, 27(10): 449-454. doi: 10.13201/j.issn.1001-1781.2013.10.005

听神经病人工耳蜗植入术中EABR监测及其疗效评估

详细信息
    通讯作者: 曹克利,E-mail:caokeli33@sina.com
  • 中图分类号: R764.7

Cochlear implantation in patients with auditory neuropathy assisted by intra-operative EABR and the therapeutic effect evaluation

More Information
  • 目的:探讨听神经病的病变部位并观察听神经病人工耳蜗植入术后的疗效。方法:选择在我院行人工耳蜗植入术的8例听神经病患者,同时筛选背景接近的8例非听神经病极重度聋人工耳蜗植入患者作为对照组进行配对。回顾性分析2组患者术前听力学资料;术中耳蜗植入前采用自制电极行电刺激听性脑干诱发反应(EABR)评估听觉通路;植入后检测神经反应遥测(NRT)、EABR;并随访术后调机T、C值,采用听觉行为分级标准(CAP) 、言语可懂度分级标准、言语识别率评估术前和开机后1年时听力言语情况。结果:8例听神经病患者术中植入前均可引出EABR波形,但是波形较正常有变异,需要刺激量加大或者调整参数,Ⅴ波潜伏期长短不一;植入耳蜗后NRT反应好,EABR和术中测试波形接近。术后开机均有听性反应,随访开机T、C值与对照组差异无统计学意义;听神经病组患者术前及开机1年CAP分别为6.50±0.94和6.90±0.77,言语识别率(双字词)分别为(85.00±11.66)%和(89.50±9.02)%,与对照组比较差异无统计学意义。结论:术前EABR可以做为评估听神经病(听同步不良患者)听觉通路的有效工具,筛选合适植入者;人工耳蜗可以帮助听神经病患者提高听力及言语能力。
  • 加载中
  • [1]

    汪吉宝,段家德,陈海华,等.听神经病106例听力学分析[J].中华耳鼻咽喉头颈外科杂志,2008,43(5):347-350.

    [2]

    莫玲燕,燕飞,刘辉,等.小儿类听神经病的临床表现[J].临床耳鼻咽喉头颈外科杂志,2011,25(22):1012-1014,1018.

    [3]

    BERLINCI M T, HOOD L J. Auditory neuropathy/dyssynchrony: its diagnosis and management[J]. Pediatr Clin North Am,2003,50: 331-340.

    [4]

    BERLIN CI H L J, MORLET T WD, LI L MKR, et al. Multi-site diagnosis and management of 260 patients with auditory neuropathy/dys-synchrony (auditory neuropathy spectrum disorder)[J]. Int J Audiol,2010,49: 30-43.

    [5]

    BUSS E L R F, BROWN CJ G A J, GROSE JH P H C. Outcome of cochlear implantation in pediatric auditory neuropathy[J]. Otol Neurotol, 2002,23: 328-332.

    [6]

    SHALLOP J K, PETERSON A, FACER G W, et al. Cochlear implants in five cases of auditory neuropathy: postoperative findings and progress[J].Laryngoscope,2001,111:555-562.

    [7]

    GIBSON W P S H. Auditory neuropathy: an update[J]. Ear Hear, 2007,28: 102S-106S.

    [8]

    PETERSON A S J, DRISCOLL C B A, BABB J S R,et al. Outcomes of cochlear implantation in children with auditory neuropathy[J]. J Am Acad Audiol,2003,14: 188-201.

    [9]

    RANCE G.Auditory neuropathy/dys-synchrony and its perceptual consequences[J]. Trends Amplif,2005, 9:1-43.

    [10]

    鲁海涛,龚树生. 听神经病与人工耳蜗植入[J]. 中华耳鼻咽喉头颈外科杂志,2009, 44(7): 604-606.

    [11]

    TRAUTWE JN P G,SININGER Y S,NELSON R.Cochlear implantation of auditory neuropathy[J].J Am Acad Audiol,2000,11:509-515.

    [12]

    周丽君,曹思远,王琦,等.92例人工耳蜗术后不同阶段康复评估效果分析[J].中国听力语言康复科学杂志,2007,(3):41-44.

  • 加载中
计量
  • 文章访问数:  195
  • PDF下载数:  246
  • 施引文献:  0
出版历程
收稿日期:  2012-12-12

目录