锥形束计算机断层扫描在人工耳蜗植入相关领域的应用进展

徐卓, 林颖, 查定军. 锥形束计算机断层扫描在人工耳蜗植入相关领域的应用进展[J]. 临床耳鼻咽喉头颈外科杂志, 2021, 35(9): 845-849. doi: 10.13201/j.issn.2096-7993.2021.09.018
引用本文: 徐卓, 林颖, 查定军. 锥形束计算机断层扫描在人工耳蜗植入相关领域的应用进展[J]. 临床耳鼻咽喉头颈外科杂志, 2021, 35(9): 845-849. doi: 10.13201/j.issn.2096-7993.2021.09.018
XU Zhuo, LIN Ying, ZHA Dingjun. The application progress of cone beam computed tomography in cochlear implantation[J]. J Clin Otorhinolaryngol Head Neck Surg, 2021, 35(9): 845-849. doi: 10.13201/j.issn.2096-7993.2021.09.018
Citation: XU Zhuo, LIN Ying, ZHA Dingjun. The application progress of cone beam computed tomography in cochlear implantation[J]. J Clin Otorhinolaryngol Head Neck Surg, 2021, 35(9): 845-849. doi: 10.13201/j.issn.2096-7993.2021.09.018

锥形束计算机断层扫描在人工耳蜗植入相关领域的应用进展

详细信息

The application progress of cone beam computed tomography in cochlear implantation

More Information
  • 加载中
  • [1]

    Niparko JK, Tobey EA, Thal DJ, et al. Spoken language development in children following cochlear implantation[J]. JAMA, 2010, 303(15): 1498-1506. doi: 10.1001/jama.2010.451

    [2]

    Contrera KJ, Betz J, Li L, et al. Quality of life after intervention with a cochlear implant or hearing aid[J]. Laryngoscope, 2016, 126(9): 2110-2115. doi: 10.1002/lary.25848

    [3]

    Loy B, Warner-Czyz AD, Tong L, et al. The children speak: an examination of the quality of life of pediatric cochlear implant users[J]. Otolaryngol Head Neck Surg, 2010, 142(2): 247-253. doi: 10.1016/j.otohns.2009.10.045

    [4]

    Shearer AE, Hansen MR. Auditory synaptopathy, auditory neuropathy, and cochlear implantation[J]. Laryngoscope Investig Otolaryngol, 2019, 4(4): 429-440. doi: 10.1002/lio2.288

    [5]

    Wanna GB, Noble JH, Gifford RH, et al. Impact of Intrascalar Electrode Location, Electrode Type, and Angular Insertion Depth on Residual Hearing in Cochlear Implant Patients: Preliminary Results[J]. Otol Neurotol, 2015, 36(8): 1343-1348. doi: 10.1097/MAO.0000000000000829

    [6]

    Rebscher SJ, Hetherington A, Bonham B, et al. Considerations for design of future cochlear implant electrode arrays: electrode array stiffness, size, and depth of insertion[J]. J Rehabil Res Dev, 2008, 45(5): 731-747. doi: 10.1682/JRRD.2007.08.0119

    [7]

    龙墨. 小儿人工耳蜗植入术后康复——机构康复和家庭康复模式探讨[J]. 中国听力语言康复科学杂志, 2008, 3: 74-76. https://www.cnki.com.cn/Article/CJFDTOTAL-TLKF200803029.htm

    [8]

    Husstedt HW, Aschendorff A, Richter B, et al. Nondestructive three-dimensional analysis of electrode to modiolus proximity[J]. Otol Neurotol, 2002, 23(1): 49-52. doi: 10.1097/00129492-200201000-00012

    [9]

    范新泰. 儿童人工耳蜗术后听觉言语发育影响因素及蜗内电极位置的研究[D]. 山东大学, 2019, 28.

    [10]

    De Cock J, Mermuys K, Goubau J, et al. Cone-beam computed tomography: a new low dose, high resolution imaging technique of the wrist, presentation of three cases with technique[J]. Skeletal Radiol, 2012, 41(1): 93-96. doi: 10.1007/s00256-011-1198-z

    [11]

    Walliczek-Dworschak U, Diogo I, Strack L, et al. Indications of cone beam CT in headand neck imaging in children[J]. Acta Otorhinolaryngologica Italica, 2017, 37(4): 270-275. doi: 10.14639/0392-100X-1219

    [12]

    Würfel W, Lanfermann H, Lenarz T, et al. Cochlear length determination using Cone Beam Computed Tomography in a clinical setting[J]. Hear Res, 2014, 316: 65-72. doi: 10.1016/j.heares.2014.07.013

    [13]

    Lan MY, Shiao JY, Ho CY, et al. Measurements of normal inner ear on computed tomography in children with congenital sensorineural hearing loss[J]. Eur Arch Otorhinolaryngol, 2009, 266(9): 1361-1364. doi: 10.1007/s00405-009-0923-x

    [14]

    Martinez-Monedero R, Niparko JK, Aygun N. Cochlear coiling pattern and orientation differences in cochlear implant candidates[J]. Otol Neurotol, 2011, 32(7): 1086-1093. doi: 10.1097/MAO.0b013e31822a1ee2

    [15]

    Alnafjan FF, Allan SM, Mcmahon CM, et al. Assessing Cochlear Length Using Cone Beam Computed Tomography in Adults With Cochlear Implants[J]. Otol Neurotol, 2018, 39(9): e757-e764. doi: 10.1097/MAO.0000000000001934

    [16]

    Nateghifard K, Low D, Awofala L, et al. Cone beam CT for perioperative imaging in hearing preservation Cochlear implantation-a human cadaveric study[J]. J Otolaryngol Head Neck Surg, 2019, 48(5): 467-474.

    [17]

    Wanna GB, Noble JH, Carlson ML, et al. Impact of electrode design and surgical approach on scalar location and cochlear implant outcomes[J]. Laryngoscope, 2014, 124(S6): S1-S7, doi: 10.1002/lary.24728

    [18]

    孟娟. 耳蜗形态学研究与人工耳蜗植入手术[D]; 郑州大学, 2017, 70-71.

    [19]

    Schuman TA, Noble JH, Wright CG, et al. Anatomic verification of a novel method for precise intrascalar localization of cochlear implant electrodes in adult temporal bones using clinically available computed tomography[J]. Laryngoscope, 2010, 120(11): 2277-2283. doi: 10.1002/lary.21104

    [20]

    Zou J, Hannula M, Lehto K, et al. X-ray microtomographic confirmation of the reliability of CBCT in identifying the scalar location of cochlear implant electrode after round window insertion[J]. Hear Res, 2015, 326: 59-65. doi: 10.1016/j.heares.2015.04.005

    [21]

    Zou J, Lahelma J, Koivisto J, et al. Imaging cochlear implantation with round window insertion in human temporal bones and cochlear morphological variation using high-resolution cone beam CT[J]. Acta Otolaryngol, 2015, 135(5): 466-472. doi: 10.3109/00016489.2014.993090

    [22]

    Ruivo J, Mermuys K, Bacher K, et al. Cone beam computed tomography, a low-dose imaging technique in the postoperative assessment of cochlear implantation[J]. Otol Neurotol, 2009, 30(3): 299-303. doi: 10.1097/MAO.0b013e31819679f9

    [23]

    Rahman TTA, Kader HAEAA, Aziz TTA. Audiological correlates of cone beam computed tomography(CBCT)in cochlear implant recipients[J]. Hear, Balance Communication, 2019, 17(4): 249-256. doi: 10.1080/21695717.2019.1644861

    [24]

    De Seta D, Mancini P, Russo FY, et al. 3D curved multiplanar cone beam CT reconstruction for intracochlear position assessment of straight electrodes array. A temporal bone and clinical study[J]. Acta Otorhinolaryngol Ital, 2016, 36(6): 499-505. doi: 10.14639/0392-100X-1279

    [25]

    宋跃帅, 龚树生. 应用锥形束CT评估人工耳蜗植入后电极形态的研究[J]. 临床耳鼻咽喉头颈外科杂志, 2018, 32(18): 1371-1373. https://www.cnki.com.cn/Article/CJFDTOTAL-LCEH201818002.htm

    [26]

    Sipari S, Iso-Mustajarvi M, Lopponen H, et al. The Insertion Results of a Mid-scala Electrode Assessed by MRI and CBCT Image Fusion[J]. Otol Neurotol, 2018, 39(10): e1019-e1025. doi: 10.1097/MAO.0000000000002045

    [27]

    Dragovic AS, Stringer AK, Campbell L, et al. Co-registration of cone beam CT and preoperative MRI for improved accuracy of electrode localization following cochlear implantation[J]. Cochlear Implants Int, 2018, 19(3): 147-152. doi: 10.1080/14670100.2017.1419548

    [28]

    Aschendorff A, Kromeier J, Klenzner T, et al. Quality control after insertion of the nucleus contour and contour advance electrode in adults[J]. Ear Hear, 2007, 28(2 Suppl): 75S-79S.

    [29]

    Dalbert A, Huber A, Veraguth D, et al. Assessment of Cochlear Trauma During Cochlear Implantation Using Electrocochleography and Cone Beam Computed Tomography[J]. Otol Neurotol, 2016, 37(5): 446-453. doi: 10.1097/MAO.0000000000000998

    [30]

    Abd El Aziz TT, El Fiky L, Shalaby MH, et al. Radiological evaluation of inner ear trauma after cochlear implant surgery by cone beam CT(CBCT)[J]. Eur Arch Otorhinolaryngol, 2019, 276(10): 2697-2703. doi: 10.1007/s00405-019-05507-4

    [31]

    Verbist BM, Joemai RM, Teeuwisse WM, et al. Evaluation of 4 multisection CT systems in postoperative imaging of a cochlear implant: a human cadaver and phantom study[J]. AJNR Am J Neuroradiol, 2008, 29(7): 1382-1388. doi: 10.3174/ajnr.A1108

    [32]

    马瑞阳, 赵宁, 李巍, 等. 多层螺旋CT及三维重建对人工耳蜗植入术的评估[J]. 临床耳鼻咽喉头颈外科杂志, 2015, 29(10): 878-881. https://www.cnki.com.cn/Article/CJFDTOTAL-LCEH201510003.htm

    [33]

    Mlynski R, Nguyen TD, Plontke SK, et al. Presentation of floating mass transducer and Vibroplasty couplers on CT and cone beam CT[J]. Eur Arch Otorhinolaryngol, 2014, 271(4): 665-672. doi: 10.1007/s00405-013-2457-5

    [34]

    Theunisse HJ, Joemai RM, Maal TJ, et al. Cone-beam CT versus multi-slice CT systems for postoperative imaging of cochlear implantation--a phantom study on image quality and radiation exposure using human temporal bones[J]. Otol Neurotol, 2015, 36(4): 592-599. doi: 10.1097/MAO.0000000000000673

    [35]

    鞠昊, 朱红华, 段涛, 等. CBCT的基本原理及在口腔各科的应用进展[J]. 医学影像学杂志, 2015, 25(5): 907-909. https://www.cnki.com.cn/Article/CJFDTOTAL-XYXZ201505045.htm

    [36]

    Zuniga MG, Rivas A, Hedley-Williams A, et al. Tip Fold-over in Cochlear Implantation: Case Series[J]. Otol Neurotol, 2017, 38(2): 199-206 doi: 10.1097/MAO.0000000000001283

    [37]

    Garaycochea O, Manrique-Huarte R, Manrique M. Intra-operative radiological diagnosis of a tip roll-over electrode array displacement using fluoroscopy, when electrophysiological testing is normal: the importance of both techniques in cochlear implant surgery[J]. Braz J Otorhinolaryngol, 2020, 86 Suppl 1: 38-40.

    [38]

    Rathgeb C, Wagner F, Wimmer W, et al. The accuracy of image-based safety analysis for robotic cochlear implantation[J]. Int J Comput Assist Radiol Surg, 2019, 14(1): 83-92. doi: 10.1007/s11548-018-1834-3

    [39]

    Labadie F, Balachandran R, Noble H, et al. Minimally invasive image-guided cochlear implantation surgery: first report of clinical implementation[J]. Laryngoscope, 2014, 124(8): 1915-1922. doi: 10.1002/lary.24520

  • 加载中
计量
  • 文章访问数:  1420
  • PDF下载数:  278
  • 施引文献:  0
出版历程
收稿日期:  2020-07-07
刊出日期:  2021-09-05

目录