Study of ceiling effect of commonly used Chinese recognition materials in post-lingual deafened patients with cochlear implant
-
摘要: 目的: 总结目前常用中文言语测试材料在语后聋人工耳蜗植入者言语识别上的效果。方法: 采用临床常用的中文言语测试材料,对32例语后聋人工耳蜗植入者进行安静条件下单音节字、扬扬格词、中文BKB语句、中文HINT语句识别率以及嘈杂噪声下HOPE语句识别阈的测试,分析比较各类测试材料在语后聋人工耳蜗植入者康复成效评价时的临床适用性。结果: 语后聋人工耳蜗植入者在安静条件下扬扬格词表、中文BKB句表和中文HINT句表的识别率达到100%的人数分别为1人、14人和4人;同时,高分数段(≥ 85%)人数分别为17人、26人和14人,均呈现出不同程度的天花板效应。反之,安静条件下单音节字识别率满分为0人,高分数段人数为6人;噪声下HOPE句表识别阈测试不受天花板效应干扰。结论: 对于相当一部分语后聋患者,现有的中文言语测试材料已出现不同程度的天花板效应。安静条件下单音节字识别率和噪声下HOPE句表识别阈测试更能相对客观地评价患者的言语识别能力。Abstract: Objective: To evaluate and compare outcomes effects of Chinese recognition materials in post-lingually deafened patients with cochlear implant.Method: Thirty-two post-lingually deafened cochlear implant users participated in the study. Each one of them was given a series of speech recognition tests including the speech recognition score of monosyllable words, spondee words, Chinese BKB sentences and MHINT in quiet, as well as speech recognition threshold of HOPE corpus in babble noise. Speech recognition scores and thresholds were compared among these test materials using histograms, scatter diagrams and statistical methods.Result: Recognition scores for spondee words, Chinese BKB sentences and MHINT were affected by ceiling effects, with 1,14 and 4 cases scored 100% respectivelty. Meanwhile, 17, 26 and 14 cases scored more than 85% correspondingly. On the other hand, speech recognition scores for monosyllable words in quiet and speech recognition threshold for HOPE corpus in babble noise were not affected.Conclusion: For a considerable part of post-lingually deafened patients using cochlear implant, some Chinese speech recognition materials have demonstrated different degrees of ceiling effects. While speech recognition scores for monosyllable words in quiet and recognition threshold for HOPE corpus in noise can evaluate the performance of speech recognition abilitymore objectively.
-
Key words:
- cochlear implantation /
- post-lingually deafened /
- speech recognition /
- ceiling effect
-
[1] HOLMES D.Lasker Foundation honours cochlearimplant pioneers[J].Lancet,2013,382:926-926.
[2] 亓贝尔,刘博,张宁,等.人工耳蜗植入者噪声环境下普通话言语测听测试方案的优化研究[J].听力学及言语疾病杂志,2011,19(4):305-310.
[3] 李佳楠,郗昕,洪梦迪,等.语后聋患者多通道人工耳蜗植入后听觉效果分析[J].临床耳鼻咽喉头颈外科杂志,2010,24(13):580-582.
[4] MACKERSIE C L.Tests of speech perception abilities.[J].Curr Opin Otolaryngol Head Neck Surg,2002,10:392-397.
[5] ZENG F G,REBSCHER S,HARRISON W,et al.Cochlear implants:system design,integration,and evaluation[J].IEEE Rev Biomed Eng,2008,1:115-142.
[6] NILSSON M,MCCAW V,SOLI S D.User manual:A minimal speech test battery for adult cochlear implant patients[M].Los Angeles:House Ear Institute,1996:4-5.
[7] NILSSON M,SOLI S D,SULLIVAN J.Development of the hearing in noise test for the measurement of speech reception thresholds in quiet and in noise[J].J Acoust Soc Am,1994,95:1085-1099.
[8] GIFFORD R H,SHALLOP J K,PETERSON A.Speech recognition materials and ceiling effects:considerations for cochlear implant programs[J].Audiol Neurootol,2008,13:193-205.
[9] SPAHR A J,DORMAN M F.Performance of subjects fit with the Advanced Bionics CII and Nucleus 3G cochlear implant devices[J].Arch Otolaryngol Head Neck Surg,2004,130:624-628.
[10] 张宇晶,郗昕.成人人工耳蜗植入相关的中文言语识别评价体系的建立[J].听力学及言语疾病杂志,2012,20(4):387-389.
[11] 张华,王靓,王硕,等.普通话言语测听单音节词表的编辑与初步等价性评估[J].中华耳鼻咽喉头颈外科杂志,2006,41(5):341-345.
[12] 郗昕,冀飞,陈艾婷,等.汉语普通话单音节测听表的建立与评估[J].中华耳鼻咽喉头颈外科杂志,2010,45(1):7-13.
[13] 李剑挥,郗昕,冀飞,等.一组汉语普通话双音节测听词表的编辑与等价性研究[J].中国基层医药,2010,17(10):1297-1298.
[14] WONG L L,SOLI S D,LIU S,et al.Development of the Mandarin hearing in noise test(MHINT)[J].Ear Hear,2007,28(2 Suppl):70S-74S.
[15] XI X,CHING T Y,JI F,et al.Development of a corpus of Mandarin sentences in babble with homogeneity optimized via psychometricevaluation[J].Int J Audiol,2012,51:399-404.
[16] 郗昕,冀飞,陈艾婷,等.怎样发展标准化的中文言语测听材料[J].中华耳科学杂志,2008,6(1):13-16.
[17] 赵阳,郗昕,冀飞,等.嘈杂语噪声下汉语语句测听中的学习效应[J].听力学及言语疾病杂志,2009,17(2):107-110.
计量
- 文章访问数: 38
- PDF下载数: 13
- 施引文献: 0