人工耳蜗植入者使用精细结构编码策略的音高和言语感知相关研究

辜萍, 郗昕, 韩东一, 等. 人工耳蜗植入者使用精细结构编码策略的音高和言语感知相关研究[J]. 临床耳鼻咽喉头颈外科杂志, 2013, 27(10): 481-484. doi: 10.13201/j.issn.1001-1781.2013.10.010
引用本文: 辜萍, 郗昕, 韩东一, 等. 人工耳蜗植入者使用精细结构编码策略的音高和言语感知相关研究[J]. 临床耳鼻咽喉头颈外科杂志, 2013, 27(10): 481-484. doi: 10.13201/j.issn.1001-1781.2013.10.010
GU Ping, XI Xin, HAN Dongyi, et al. Speech and pitch perception with the new fine structure speech coding strategy[J]. J Clin Otorhinolaryngol Head Neck Surg, 2013, 27(10): 481-484. doi: 10.13201/j.issn.1001-1781.2013.10.010
Citation: GU Ping, XI Xin, HAN Dongyi, et al. Speech and pitch perception with the new fine structure speech coding strategy[J]. J Clin Otorhinolaryngol Head Neck Surg, 2013, 27(10): 481-484. doi: 10.13201/j.issn.1001-1781.2013.10.010

人工耳蜗植入者使用精细结构编码策略的音高和言语感知相关研究

  • 基金项目:

    国家自然科学基金(No:61003094)

    香港Gener-al Research Fund(GRF)(No:780109M)

详细信息
    通讯作者: 郗昕,E-mail:xxi@bbn.cn
  • 中图分类号: R764.35

Speech and pitch perception with the new fine structure speech coding strategy

More Information
    Corresponding author: XI Xin, E-mail: xxi@bbn.cn
  • 目的:通过评估MED-EL人工耳蜗植入者使用FS4编码策略和HDCIS编码策略时的音乐音高和言语感知能力,探索提供精细结构信息的编码策略对人工耳蜗使用效果的影响。方法:12例植入MED-EL人工耳蜗的语后聋患者分别在FS4和HDCIS编码策略下编程调试,并进行音高差阈、音高方向和言语感知测试,比较2种编码策略下各项测试的结果,并进行统计学分析。结果:在FS4编码策略下的音高差阈和音高方向测试结果均显著优于HDCIS编码策略下的测试结果,测试得分差异有统计学意义(P<0.05)。2种编码策略下的汉语声调、声母和韵母识别得分均差异无统计学意义(P>0.05)。结论:FS4编码策略对人工耳蜗植入者的音乐音高感知有较大帮助。在汉语声调、声母和韵母识别方面,FS4和HDCIS编码策略的使用效果差异不大。
  • 加载中
  • [1]

    COSETTI M K, WALTZMAN S B. Cochlear implants: current status and future potential[J]. Exp Rev Med Devices,2011,8:389-401.

    [2]

    王坚, 蒋涛, 曾凡刚. 听觉科学概论[M]. 北京: 中国科学技术出版社, 2005: 391-394.

    [3]

    平利川,原猛,郗昕,等.人工耳蜗使用者音乐感知评估系统的设计[J].声学技术, 2010, 29(5): 512-517.

    [4]

    WILSON B S, SCHATZER R, LOPEZ-POVEDA E A, et al. Two new directions in speech processor design for cochlear implants[J]. Ear Hearing, 2005, 26:73S-81S.

    [5]

    赵阳, 郗昕, 冀飞,等.嘈杂语噪声下汉语语句测听中的学习效应[J]. 听力学及言语疾病杂志, 2009, 17(2): 107-110.

    [6]

    ARNOLDNER C, RISS D, BRUNNER M, et al. Speech and music perception with the new fine structure speech coding strategy: preliminary results[J]. Acta Otolaryngologica, 2007, 127: 1298-1303.

    [7]

    刘博. 人工耳蜗植入者的声调研究与评价[J].中国医学文摘耳鼻咽喉科学, 2009, 24(4): 260-261.

    [8]

    SCHATZER R, KRENMAYR A, AU D K, et al. Temporal fine structure in cochlear implants:preliminary speech perception results in Cantonese-speaking implant users[J]. Acta oto-laryngologica,2010,130:1031-1039.

    [9]

    QI B E,HAN D M. Effects of temporal fine structure stimulation on Mandarin speech recognition in cochlear implant users[J]. Acta Otolaryngologica,2012,132:1183-1191.

    [10]

    RISS D, HAMZAVI J S, KATZINGER M, et al. Effects of fine structure and extended low frequencies in pediatric cochlear implant recipients[J]. Int J Pediatr Otorhinolaryngol,2011,75:573-578.

    [11]

    SEEBENS Y, DILLER G. Improvements in speech perception after the upgrade from the TEMPO+ to the OPUS 2 audio processor[J]. ORL,2012,74:6-11.

  • 加载中
计量
  • 文章访问数:  245
  • PDF下载数:  175
  • 施引文献:  0
出版历程
收稿日期:  2013-01-26

目录